optel@optel.eu +48 71 329 68 53
Case studies · Energy / biomethane

Ultrasonic gas metrology – biomethane quality in real time

Injecting biomethane into the grid requires continuous control of its energy parameters. Research published by our team in the International Journal of Oil, Gas and Coal Technology confirmed that opTim 2.0 determines the Wobbe index with high precision without costly gas chromatography.

Ultrasonic gas metrology – biomethane quality in real time

Challenge

Gas chromatographs are accurate but expensive to buy and maintain, need calibration gases and work cyclically with a delay of several minutes. Grid operators and biomethane plants need a continuous, maintenance-free solution that withstands industrial conditions.

OPTEL solution

  • Speed of sound to ±1 cm/s: precise time-of-flight analysis of the ultrasonic wave in the gas mixture.
  • Attenuation analysis at 1 MHz: measurement of acoustic absorption, which depends on the molecular composition of the gas.
  • Sensor data fusion: acoustic parameters combined with temperature and CO₂ concentration let correlation algorithms determine calorific value and Wobbe index in real time.

Results

  • Maintenance-free continuous operation: no consumables and no calibration gases.
  • Immediate process response: real-time control of propane dosing to keep the required calorific value.

Key parameters

  • Speed of sound resolution: ±1 cm/s
  • Attenuation measurement: 1 MHz
  • Additional inputs: temperature, CO₂ concentration
  • Outputs: calorific value, Wobbe index

Developing a biomethane plant or a gas blending system? Check how the opTim 2.0 measuring unit can be integrated.

Start with a feasibility study

← All case studies

Custom ultrasonic development

Need a solution for a specific measurement problem?

OPTEL can evaluate the measurement physics, transducers, electronics and software before a full system is built.

Start with a feasibility studyContact OPTEL