GraSonics
High Sensitive Wideband Graphene Ultrasonic Transducers
Project summary
Development of wideband CMUT ultrasonic transducers with a graphene membrane for highly sensitive measurement systems.
Project description
GraSonics used ultrathin, highly elastic graphene layers as vibrating membranes of electrostatically driven capacitive micromachined ultrasonic transducers (CMUT). The aim was to emit and receive wideband ultrasound in air at frequencies above 300 kHz – short, strong pulses with a wide receiving bandwidth, as needed for precise measurement, positioning and imaging.
The project brought together three partners from the Czech Republic, Germany and Poland with competences in graphene, MEMS and ultrasonics. A functional graphene ultrasound transducer was built and validated in the laboratory, reaching technology readiness level TRL 4.
OPTEL's role
OPTEL built the laboratory test bench for the acoustic and mechanical characterisation of the graphene membranes produced by the partners – including dedicated transmit/receive electronics, an alpha-beta angular scanner, adapted OPBOX/opLabBox acquisition and laser interferometry of membrane deflection – and prepared the ultrasonic holographic camera as the target demonstrator for the graphene transducers.
Project information
| Acronym | GraSonics |
|---|---|
| Programme | M-ERA.NET Call 2021 (NCBR, TA ČR, SMWK) |
| Grant / contract no. | M-ERA.NET3/2021/72/GraSonics/2022 |
| Duration | 01.06.2022 – 31.05.2025 |
| Partners | J. Heyrovsky Institute of Physical Chemistry CAS (CZ, coordinator), Fraunhofer ENAS (DE), OPTEL (PL) |
| Project website | https://m-era.net/materipedia/2021/grasonics |
Need a solution for a specific measurement problem?
OPTEL can evaluate the measurement physics, transducers, electronics and software before a full system is built.
Start with a feasibility studyContact OPTEL